Table 2. Firmware Checkpoints (continued)
Checkpoint Description Action/ Possible Failing FRU
E709 Create VPD via SPCN. Replace the system planar,
Location: P1. See the note on page
78.
E70A Create service processor VPD. Replace the system planar,
Location: P1. See the note on page
78.
E8xx RTAS initialization problem. Call for support.
EAA1 Probe PCI-PCI bridge. Follow the repair actions for
checkpoint E151.
Note: If you receive a four-digit code in the range of E1xx to EFFF that is not listed in
the table above, go to “MAP 1540: Minimum Configuration” on page 52.
Chapter 4. Checkpoints 95