Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
460F 24A4 I/O system and error code
generation/logging detected 6W 500
MHz processor fault
Processor card, Location: P1-C1
460F 25B6 I/O system and error code
generation/logging detected 650W
power supply fault
Power supply Location: V1 or V2 or
V3
460F 25BB I/O system and error code
generation/logging detected 1W 600
MHz processor fault
Processor card, Location: P1-C1
460F 25BD I/O system and error code
generation/logging detected 2W 600
MHz processor fault
Processor card, Location: P1-C1
460F 25BE I/O system and error code
generation/logging detected 4W 600
MHz processor fault
Processor card, Location: P1-C1
460F 25BF I/O system and error code
generation/logging detected 6W 668
MHz processor fault
Processor card, Location: P1-C1
460F 263D I/O system and error code
generation/logging detected memory
filler fault
Memory filler card, Location: P1-M1
or P1-M2
460F 281F I/O system and error code
generation/logging detected SSA
backplane fault
SSA 6-pack, Location: B1 or B2
460F 282E I/O system and error code
generation/logging detected system
board fault
1. System board, Location: P1
2. Processor card, Location: P1-C1
460F 283F I/O system and error code
generation/logging detected SCSI
backplane fault
SCSI 6-pack, Location: B1 or B2
460F 288D I/O system and error code
generation/logging detected memory
riser fault
Memory riser card, Location: P1-M1
or P1-M2
460F 2A00 I/O system and error code
generation/logging detected 6W 4M
500 MHz processor fault
Processor card, Location: P1-C1
460F 300A I/O system and error code
generation/logging detected 32MB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460F 300B I/O system and error code
generation/logging detected 128MB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
460F 300C I/O system and error code
generation/logging detected 256MB
DIMM fault
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn